KP826 multi-gas detector, is a one gas detecting instrument which can be equipment with one kind gas sensor or several kinds gas sensor for detecting different gases simultaneously. It adopts dot matrix display technology and various toxic gas sensors. It can be configured with single, two in one, three in one, four in one, five in one or any other four kind toxic gas sensors for working.
KP826 multi-gas detector with LCD display, has high sensitivity and fast response time. With audio sound&light alarm,it adapts to rather complex environment for concentration monitoring. The product is suitable for chemical, pharmaceutical, municipal, water treatment, telecommunications, archeology, laboratories, cold storage, wine and other places. You can choose the gas that you need to detect from the below gas list;
The KP826 is a portable multi-gas detector designed for reliable gas monitoring in industrial environments. Compact and easy to carry, it provides real-time detection with enhanced safety alarm functions.
Supports up to 5 gases real-time detection (customizable)
Large digital display for clear and easy reading
Triple alarm system: sound, light, and vibration
Power-on self-test with sound & light alarm indication
Data & Connectivity
Built-in data storage with up to 3,000 alarm records
Optional data upload to computer for monitoring and analysis
Supports alarm record export and management
Design & Protection
Compact and portable design for field use
IP65 protection: dustproof and waterproof
Durable construction for harsh environments
Reliable, portable, and smart—KP826 ensures safer gas detection anytime, anywhere.
about 8 hours for flammable gas, about 200 hours toxic gas
Display
large screen LCD
Alarm
sound, light, vibration triple alarm
Direct reading
instantaneous value
Working temperature
-10 ℃ - 55 ℃
Instrument size
126mm * 66mm * 33mm
Working humidity
≤93% RH
Instrument weight:
210g
Domestic mark
PA, CNex, CE
Explosion protection number
CLEx24.1020
Explosion-proof mark
Ex ia IIC T4 Ga
PA
2014C203-41
Common Gas Parameter listing
Gas detected
Measuring Range
Optional Range
Resolution Rat
Response Time
LEL -combustible gas
0-100%LEL
0-100%VOL(Infrared or catalytic )
1%LEL/1%vol
≤10s
carbon monoxide
0-1000PPm
0-500/2000/5000PPm
0.1/1PPm
≤10s
TVOC
0-100PPM
0-100PPM
0.1PPm/1PPM
≤15s
hydrogen
0-100%LEL
0-1000PPM
1%LEL/1PPM
≤15s
natural gas
0-100%LEL
0-100%LEL
1%LEL
≤10s
Oxygen-O2
0-30%VOL
0-30%、0-100%VOL
0.1%vol
≤10s
ozone
0-10PPm
0-20、100PPm
0.01PPm/0.1PPM
≤15s
hydrogen sulfide-H2S
0-100PPm
0-50、200、1000PPm
1/0.1PPm
≤10s
Methane-CH4
0-100%LEL
0-100%VOL
1%LEL/1%vol
≤10s
fluorine
0-10PM
0-1、10PPM
1/0.1PPm
≤15s
hydrogen chloride
0-20PPm
0-20/50PPm/100PPM
0.01/0.1PPm
≤15s
Nitrogen-N2
0-30%VOL
0-30%VOL、100%VOL
0.1%LEL/1PPM
≤10s
hydrogen
0-100%LEL
0-1000PPm
1%LEL/0.1PPm
≤15s
chlorine
0-20PPm
0-10、100PPm
0.1PPm
≤15s
ammonia gas
0-100PPm
0-50、500、1000PPm
1/0.1PPm
≤15s
oxynitride
0-20PPm
0-50、1000PPm
0.1/1PPm
≤15s
methanal
0-20PPm
0-50、100PPm
1/0.1PPm
≤15s
sulfur dioxide
0-20PPm
0-50、1000PPm
0.1/1PPm
≤15s
nitric oxide
0-250PPm
0-500、1000PPm
1PPm
≤15s
nitrogen dioxide
0-20PPm
0-50、1000PPm
0.1/1PPm
≤15s
phosphine
0-20PPm
0-20、100PPm
0.1PPm
≤15s
acrylonitrile
0-100PPM
0-100PPm
0.1/1PPm
≤15s
carbon dioxide
0-5000PPm
0-1%/5%/10%VOL(Infrared )
1PPM/0.01%VOL
≤15s
hydrogen fluoride
0-10PPm
0-1、10、50、100PPM
0.01/0.1PPm
≤15s
Xylene/methylbenzene
0-20PPm
0-5、10、50、100PPm
0.01/0.1PPm
≤15s
oxirane
0-100PPm
0-100PPm
1/0.1PPm
≤15s
For other gases and measuring ranges, please contact us directly!
Product list
One detector, one set of charger & line, one calibration cover, one operation manual, one quality certificate, one piece of guarantee card, and factory inspection report.