Zhongan S300 gas detector is developed according to national standards and national product quality and technical requirements. The instrument can meet the requirements of sound and light alarm prompt on gas detection site and real-time display and monitoring of gas concentration on site. Infrared remote control type is adopted for field debugging, and parameter setting can be carried out without opening the cover.
Zhongan S300 gas detector is developed according to national standards and national product quality and technical requirements. The instrument can meet the requirements of sound and light alarm prompt on gas detection site and real-time display and monitoring of gas concentration on site. Infrared remote control type is adopted for field debugging, and parameter setting can be carried out without opening the cover.
Zhongan S300 gas detector can convert the gas concentration signal leaked in the air into electrical signal remote transmission. The instrument can adopt the output mode of three wire system 4 ~ 20mA or four bus RS485, which has the advantages of long transmission distance and anti-interference.
Zhongan S300 gas detector is widely used to detect the leakage concentration of combustible gas and toxic and harmful gas in industrial environment.
The below gases are available
Gas detected
Measuring Range
Optional Range
Resolution Ratio
Response Time
LEL -combustible gas
0-100%LEL
0-100%VOL(Infrared or catalytic )
1%LEL/1%vol
≤10s
carbon monoxide
0-1000PPm
0-500/2000/5000PPm
0.1/1PPm
≤10s
TVOC
0-100PPM
0-100PPM
0.1PPm/1PPM
≤15s
hydrogen
0-100%LEL
0-1000PPM
1%LEL/1PPM
≤15s
natural gas
0-100%LEL
0-100%LEL
1%LEL
≤10s
Oxygen-O2
0-30%VOL
0-30%、0-100%VOL
0.1%vol
≤10s
ozone
0-10PPm
0-20、100PPm
0.01PPm/0.1PPM
≤15s
hydrogen sulfide-H2S
0-100PPm
0-50、200、1000PPm
1/0.1PPm
≤10s
Methane-CH4
0-100%LEL
0-100%VOL
1%LEL/1%vol
≤10s
fluorine
0-10PM
0-1、10PPM
1/0.1PPm
≤15s
hydrogen chloride
0-20PPm
0-20/50PPm/100PPM
0.01/0.1PPm
≤15s
Nitrogen-N2
0-30%VOL
0-30%VOL、100%VOL
0.1%LEL/1PPM
≤10s
hydrogen
0-100%LEL
0-1000PPm
1%LEL/0.1PPm
≤15s
chlorine
0-20PPm
0-10、100PPm
0.1PPm
≤15s
ammonia gas
0-100PPm
0-50、500、1000PPm
1/0.1PPm
≤15s
oxynitride
0-20PPm
0-50、1000PPm
0.1/1PPm
≤15s
methanal
0-20PPm
0-50、100PPm
1/0.1PPm
≤15s
sulfur dioxide
0-20PPm
0-50、1000PPm
0.1/1PPm
≤15s
nitric oxide
0-250PPm
0-500、1000PPm
1PPm
≤15s
nitrogen dioxide
0-20PPm
0-50、1000PPm
0.1/1PPm
≤15s
phosphine
0-20PPm
0-20、100PPm
0.1PPm
≤15s
acrylonitrile
0-100PPM
0-100PPm
0.1/1PPm
≤15s
carbon dioxide
0-5000PPm
0-1%/5%/10%VOL
(Infrared )
1PPM/0.01%VOL
≤15s
hydrogen fluoride
0-10PPm
0-1、10、50、100PPM
0.01/0.1PPm
≤15s
Xylene/methylbenzene
0-20PPm
0-5、10、50、100PPm
0.01/0.1PPm
≤15s
oxirane
0-100PPm
0-100PPm
1/0.1PPm
≤15s
For other gases and measuring ranges, please contact us directly!
Functions Features