1.Flame retardant and anti - chemical adhesive cloth property
fabric thickness: 0.45±0.05mm
tensile strength: warp and weft ≥450N/5cm
tear resistance: ≥50N
acid and alkali resistance: 10mm liquid column lh (80%H2S04,
60%HN03, 30%HCL。6.1M01/LNA0H) impervious
thermal aging property: 125 x 24h non-stick,Not brittle
cold-resistant property: -25×5Min, Fold 180 degrees without a crack.
Gas resistance: 120#The gasoline is soaked for 30s without crack or sticky.
flame retardant property: after flame time≤2s, after flame time≤10s, damaged length
≤10cm, no drop
the resistance of the fabric to radiant heat penetration: (1 Kw/M2 x 30S Internal surface temperature rise)《 25°C
2.Protective boot performance
The insulation performance of the shoe sole: ≥5000V
Puncture resistance: ≥780N
Waterproof performance of boots: Soak 2h without seepage
3.Protective clothing property
Adhesive strength of adhesive tape: ≥0.78kn/m
Resistance to water leakage: No leakage of 5 3L/min sprinkler head for 15min.
Proof and air tight type: 1650PA + 50Pa 6Min pressure drop name 300Pa.
The overall weight: ≤6kg
4.Main component property
Performance of overpressure exhaust valve: Air tightness &15S, ventilation resistance 78-118pa.
Performance of ventilation system distribution valve: The maximum air supply is >30L/min, and the quantitative gas supply is 5UMin.
5.Specification of protective clothing
XL:More than 180CM L: 175-180cm M: 170-175cm S: below 170CM.
Memo: The clothes of fire-fighting equipment are divided into the simple protective clothing and the full enclosed type of protective clothing, the thermal insulation suit, the fire protection suit, the fire fighting suit and so on. The figure above is a simple anti-chemical suit.